SPF and torch down

 
Thread Tools Search this Thread Display Modes
Old 06-21-2009, 08:20 AM   #1
Junior Member
 
bacon8685's Avatar
 
Join Date: Jun 2009
Posts: 4
Default

SPF and torch down


I am a maintenance man at a humane society animal shelter in florida and we have a thrift store that used to be a old hardware store. it has developed leaks all over the roof, and has a raised section of the roof that is about 3 feet taller then the rest of it. my question is that the raised section have a type of roof system that appears to be like a spf system but i'm not 100% sure my boss has found a community service worker that does roofs and he said you can put torch down over that sort of roof, does anyone know if this is true wheni ran into it working for a general contractor we were told that type of roofing system has to be removed before anything is put over it. does anyone know ?


Last edited by bacon8685; 06-21-2009 at 08:21 AM. Reason: needed to add something
bacon8685 is offline  
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Old 06-21-2009, 03:46 PM   #2
Super Moderator
 
Ed the Roofer's Avatar
 
Join Date: Sep 2008
Posts: 755
Default

Re: SPF and torch down


No, you can not, but I don't have personal experience, just information from other roofers on the net.

Either patch the SPUF, Sprayed Poly-Urethane Roof, or remove and replace it.

Ed
Ed the Roofer is offline  
Old 06-22-2009, 09:09 AM   #3
Senior Member
 
Grumpy's Avatar
 
Join Date: Oct 2008
Location: Chicago, IL
Posts: 1,562
Default

Re: SPF and torch down


In any of the specs I heave read I have never seen spf as a suitable substrate for modified bitumen. Infact come to think of it I have never seen spf as a suitable substrate for any roofing system other than those that are liquid applied, like elastomeric built up or polyurea.


This guy may "do roofs" but is he a roofer?
__________________
-Grumpy
Chicago Gutters Chicago Roofing
Grumpy is offline  
Old 06-22-2009, 10:26 AM   #4
Junior Member
 
bacon8685's Avatar
 
Join Date: Jun 2009
Posts: 4
Default

Re: SPF and torch down


He says that he is a "sub contractor" but as it is community service mandaited by the court system here in florida there's really no way for us to verify that he is what he says he is. In my opinion he doesn't know his butt from a hole in the ground but its my boss that trust him. i just wanted to see if it was safe or even possible to put torch down over spf roofing system and in my opinion i do not like the spf system we've had nothing but trouble outta it. but we are a non profit organization so funds to replace it are very very very low so we have to do patch and go work.
bacon8685 is offline  
Old 06-22-2009, 02:06 PM   #5
Senior Member
 
Grumpy's Avatar
 
Join Date: Oct 2008
Location: Chicago, IL
Posts: 1,562
Default

Re: SPF and torch down


In FLorida installing roofing without proper licensing is a felony. He should be able to provide you with documentation of his ROOFING licenses(s). I says plural licenses, since I Know each county has their own licensing.

Torching to it will ruin the spf for sure. Try contacting a company who specializes in restoring spf. Maybe try spray maxx
__________________
-Grumpy
Chicago Gutters Chicago Roofing
Grumpy is offline  
Old 06-22-2009, 02:57 PM   #6
Junior Member
 
bacon8685's Avatar
 
Join Date: Jun 2009
Posts: 4
Default

Re: SPF and torch down


Thats what i have figured and read I know when i worked for a general contractor we had so many diffeerent lic. it wasn'te ven funny. I figured it would ruinu the roof and end up costing more damage so basically a complete tear down and start over from the deck up, or has nayone heard of a sealent called coolseal we used to use it on mobile homes and flat to slight pitched roofs was wondering if there was a less expensive alternative to that.
bacon8685 is offline  
Old 06-22-2009, 08:03 PM   #7
Member
 
SinglePlyGuy's Avatar
 
Trade: CommercialRoofing
Join Date: Jan 2009
Location: NJ
Posts: 71
Default

Re: SPF and torch down


I would HIGHLY recommend NOT putting torch down directly over SPF.

As Ed mentioned, coat the roof or get rid of it. Depending on the deck makeup you "MAY" be able to get away with Mechanically fastening through it with a seperator board and a membrane.

I would lean toward getting rid of it personally...esp if it is bad shape and has moisture.
SinglePlyGuy is offline  
Old 06-23-2009, 08:56 AM   #8
Senior Member
 
Grumpy's Avatar
 
Join Date: Oct 2008
Location: Chicago, IL
Posts: 1,562
Default

Re: SPF and torch down


Cool seal is about as cheap as you can get without sacrificing quality. The stuff sold on the shelves at home depot may look similiar to other elastomeric products like cool seal; however their % of solids, or lack there of, make them basically house paint and you won't accomplish anything by installing the thinner products.
__________________
-Grumpy
Chicago Gutters Chicago Roofing
Grumpy is offline  
Old 06-30-2009, 09:25 PM   #9
Member
 
rwolfe's Avatar
 
Join Date: May 2009
Posts: 62
Default

Re: SPF and torch down


bacon,

You absolutely cannot torch a mod over a puf roof. (funny someone would mention that though. Typical florida roofing)The only thing you can do is apply an elastomeric coating or slap another crappy puf over the top. Assuming the puf is not under warranty, there are a number of elastomerics you can use. But I've have yet to see a puf roof that wasn't cratoring all over the place. Shame on the owner for buying the junk. But you have a choice of several APOC or Neogard products that will do what they claim to be able to do.

rw.

If your anywhere near fort lauderdale, I'll get it taken care of for you.

rw
rwolfe is offline  
Old 06-30-2009, 09:30 PM   #10
Member
 
rwolfe's Avatar
 
Join Date: May 2009
Posts: 62
Default

Re: SPF and torch down


Quote:
Originally Posted by bacon8685 View Post
Thats what i have figured and read I know when i worked for a general contractor we had so many diffeerent lic. it wasn'te ven funny. I figured it would ruinu the roof and end up costing more damage so basically a complete tear down and start over from the deck up, or has nayone heard of a sealent called coolseal we used to use it on mobile homes and flat to slight pitched roofs was wondering if there was a less expensive alternative to that.
BTW.

The owner bought a puf system because he was looking for less alternative. You'll be dealing with this roof for the life of the puf. Take that to the bank. If the puf is in decent shape, don't look for the cheap way out when considering a coating. Or that will be the second mistake made on that roof.
rwolfe is offline  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Join Now... It's Fast and FREE!

Privacy Badge
I am a professional contractor
I am a DIY Homeowner
ContractorTalk.com is for
PROFESSIONAL CONTRACTORS ONLY!

At ContractorTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?


Content Relevant URLs by vBSEO 3.6.0