Corrugated panels wrong way?
I'm bidding on a job right now that has me perplexed. Maybe some of you have dealt with this and its not that uncommon. Ok, Commercial building in a strip mall. 48 by 92. The slope goes from front (south) to back (north). Panels run from left to right. There is some modified or some epoxy to make it flat on top.The roof supports are on i beams which run east to west. The supports are on i beams which run north to south. So panels sit east to west. On the roof to the west is another building which the wall extends well above the roof. The east side is a small parapet divider. Thoughts anyone?
|
|
|
|
|
|
#2 |
|
Senior Member
Join Date: Oct 2008
Location: Chicago, IL
Posts: 1,574
|
Re: Corrugated panels wrong way?
Sorry, but you're going to have to post some pics. I'm guessing that the metal you are seeing from the bottom (?) is the metal deck, and if so will likely have a wood plywood over it. Or are you seeing it currogated from the top side? Really pics would be a major help.
|
|
|
|
|
|
#3 |
|
Junior Member
Trade: Exterior Expert
Join Date: Feb 2010
Location: Merrillville, Indiana
Posts: 26
|
Re: Corrugated panels wrong way?
Yeah the corrugated i see is from the bottom. I will try to get some pics up asap. There is significant leaking in several spots. The metal is rusted and disintegrating. It doesnt appeat to have plywood above, but will double check if i can get back out. Thanks Grumpy
|
|
|
|
|
|
#4 |
|
Senior Member
Join Date: Oct 2008
Location: Chicago, IL
Posts: 1,574
|
Re: Corrugated panels wrong way?
I've seen insulation specifically engineered to fit inbetween ribs in various types of metal decking. Primarily used on standing seam however. If it's a flat roof, and it's some kind of metal deck (is it actual currogated or like aq F or B type roof deck?) it could simply have 1 1/2" insulation over the metal and the roof membrane installed ontop of the insulation. This is a very common spec for metal decks.
|
|
|
|
|
|
#5 |
|
Customer Benefitter
Trade: Roofing Specialiist, Foam Specialist, Seamless systems
Join Date: Nov 2008
Location: Illinois IL
Posts: 57
|
Re: Corrugated panels wrong way?
Yeah, sounds like Corrugated decking to me on bar joists on I beams.
|
|
|
|
|
|
#6 |
|
Junior Member
Trade: Sales, Specifying; BUR, Coatings, Single Ply.
Join Date: Dec 2009
Location: Oshkosh, WI
Posts: 16
|
Re: Corrugated panels wrong way?
It sounds like he's saying the panel rib runs perpendicular to the slope.
Is this a deck panel or a roof panel? |
|
|
|
|
|
#7 |
|
Junior Member
Trade: Exterior Expert
Join Date: Feb 2010
Location: Merrillville, Indiana
Posts: 26
|
Re: Corrugated panels wrong way?
My best guess is a deck panel. and yes it runs perpindicular to the slope. On topof the roof it is flat and smooth. I come from resdential construction and roofing and commercial is greek to me. Ive dabbled in it but primarily modified. Grumpy has been a wealth of knowledge and i think pointed me in the right direction.
|
|
|
|
|
|
#8 |
|
Customer Benefitter
Trade: Roofing Specialiist, Foam Specialist, Seamless systems
Join Date: Nov 2008
Location: Illinois IL
Posts: 57
|
Re: Corrugated panels wrong way?
Nick, Im an hour from Merrilville if you need any assistance.
__________________
www.roseroofing.net/ Seamless polyurea membrane roofing systems for metal and membrane systems, Seamless Foam roofing that pays for itself via energy efficiencies, All types of roofing maintenance, service, and repair. Illinois IL |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Whats wrong with this picture? | jamesfl | Roofing Pictures | 14 | 07-02-2009 04:04 AM |
| Vinyl Soffit Panels | user182 | Ventilation Problems, Solutions And Theory | 9 | 04-17-2009 01:33 AM |
| Go to Page... |