My personal choice is PVC.

akismith678 is offline  
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Old 02-09-2010, 04:17 PM   #52
Tile roof & PV systems
 
Joe Roofer's Avatar
 
Join Date: Nov 2009
Location: Southwest desert
Posts: 33
Default

Re: What is your favorite flat roofing system?


I've done a lot of modified, standing seam and exposed fastened metal, some elastomeric coating (some with a guy named Aaron?) and one house with TPO. I hate the coating, junk is how I feel about. Freaking mess. I know of too many leaks for it to be a functional system (fortunately not on any I had anything to do with yet. Aaron's work really stinks.) Torch I dislike. Mess on the shoes and the fear of fire is ever present. TPO all the way! I'm sold and have complete faith in the product. The only good thing about having so many houses here with the coating on them is I know TPO will be on them shortly.

Last edited by Joe Roofer; 02-09-2010 at 04:47 PM.
Joe Roofer is offline  
Old 02-09-2010, 04:35 PM   #53
Tile roof & PV systems
 
Joe Roofer's Avatar
 
Join Date: Nov 2009
Location: Southwest desert
Posts: 33
Default

Re: What is your favorite flat roofing system?


Quote:
Originally Posted by yanceyman1 View Post
Altough I agree with most of you, I still like torch down single ply. Incase you didn't know this, many of the companies that Ed has a preference to have been involved in MANY class action suits due to material failure. What do these companies do? They file chapter 11 and continue with a new name and a new "formula". I am currently bidding a Trocal roof that has failed at all the flashing details, (I'm adding pics.). When I attempted to help the owner with warranty issues I was told, "wait in line".
I have been doing torch for 20 years and have never had a material failure. A few install issues, but not material. YES, PVC and TPO are wonderfull to work with. But when you are running 35 guys with welders, who has time to, "pick" all their seams. With torch I can simply do my final walk visually and pick up install issues.
So call me old school, but after millions of dollars of torch decks with little or no problems for 20 years, I'll dance with who brought me here.
That's a improper use of unreinforced flashing, a roofer failure by the look of it. I hope my pipes don't do that. It looks like a simple repair none the less.

Last edited by Joe Roofer; 02-09-2010 at 05:43 PM.
Joe Roofer is offline  
Old 02-10-2010, 08:44 AM   #54
Senior Member
 
RooferJim's Avatar
 
Join Date: Oct 2008
Posts: 163
Default

Re: What is your favorite flat roofing system?


TPO is not as time tested as PVC membrane though. I know of a lot of PVC roofs holding well after twenty and even thirthy year service. EPDM Rubber roofs the same, although the laps and flashings will in many cases need to be redone with EPDM. With the taped seams now I think they will have less of a maintenence issue.
RooferJim is offline  
Old 02-10-2010, 10:44 AM   #55
Roofer530
 
yanceyman1's Avatar
 
Trade: project manager/lifelong journeyman
Join Date: Jan 2010
Posts: 26
Default

Re: What is your favorite flat roofing system?


Thanks for the imput joe. But those are pics of the manufacture designed and fabricated flashing kits. You know the kind, mostly commercial roofs, you send them a set of prints and they send out your roof. You weld it together and BAM!, you got a new roof. Until BOOM! it starts to leak! And then noone wants to take responsibility.
__________________
"The Best Way To Appreciate Your Job Is To Imagine Yourself Without One". OSCAR WILDE
yanceyman1 is offline  
Old 02-10-2010, 04:45 PM   #56
Senior Member
 
RooferJim's Avatar
 
Join Date: Oct 2008
Posts: 163
Default

Re: What is your favorite flat roofing system?


Are you sure it was Trocal ? They have not been around for a while.
RooferJim is offline  
Old 02-11-2010, 05:10 AM   #57
Roofer530
 
yanceyman1's Avatar
 
Trade: project manager/lifelong journeyman
Join Date: Jan 2010
Posts: 26
Default

Re: What is your favorite flat roofing system?


Yes, I could tell by the big, "Tro-Cal" stamp on the material.
__________________
"The Best Way To Appreciate Your Job Is To Imagine Yourself Without One". OSCAR WILDE
yanceyman1 is offline  
Old 02-11-2010, 08:18 AM   #58
Senior Member
 
RooferJim's Avatar
 
Join Date: Oct 2008
Posts: 163
Default

Re: What is your favorite flat roofing system?


Then it must be older than 12 years
RooferJim is offline  
Old 02-11-2010, 09:45 AM   #59
Tile roof & PV systems
 
Joe Roofer's Avatar
 
Join Date: Nov 2009
Location: Southwest desert
Posts: 33
Default

Re: What is your favorite flat roofing system?


Still, IMO if it's just a few curbs (or other small details) it only needs a repair that may take only a few hours. If it was the field then it needs a whole new roof. If you can sell it by all mean sell it. I see one ply modified as a down grade from PVC/TPO. Two ply might be in the ball park.
Joe Roofer is offline  
Old 02-11-2010, 04:10 PM   #60
RoofGuy
 
Ansel's Avatar
 
Trade: Operations Manager - Leak Investigation - Sales + a Bunch of Other Jobs I Don't Know How to Do!
Join Date: Jan 2010
Location: Aurora, IL - Fox Valley Area
Posts: 42
Default

Re: What is your favorite flat roofing system?


Best Roof for Flat ....

All things being equal I would have to say a three ply hot type IV glass (JM is best choice) with modified cap (torch on Derbigum) .... or mop-on Tamko SBS and then flood coat and gravel .....

But the real question is what is the best roof for the particular job ..... Most residential homes are well served by TPO - EPDM or Modifieds .... Once again, depends on the particular job ..... each has pluses and minuses .... but with respect to the TPO the jury is still out on that membrane .... see below from the MRCA dated 2/10/10..... Not good for TPO ......

February 10, 2010


T&R Committee Advisory on TPO
Information is being circulated in the industry indicating that high solar loading and elevated temperature lead to the premature exhaustion of anti aging components such as anti oxidants, UV absorbers and heat and light stabilizing compounds within TPO. This could lead to the breakdown of the sheet in affected areas.

This also might explain some reported problem applications with localized deterioration of membrane. One manufacture has recently changed formulation to account for this problem; another advises their product not be "subjected" to high thermal or solar loading; while others remain silent. Southern states appear to have this problematic local condition due to the heat load these roofs experience.

The committee believes that enough information has surfaced concerning TPO accelerated weathering due to solar or thermal loading to advise members to:

Review roof plans for situations where sun light is reflected back on membrane; such as areas below metal and glass or highly reflective curtain walls, or high profile reflective wall flashings.

Look for heat emitting equipment or heat exhausting vents or dark emissive materials laid on the roof that can elevate the temperature of the covered sheet; as well as areas under or over elevated temperature operations.

If situations exist that may commonly elevate temperatures over 160 degrees or increase solar loads beyond "normal" incoming solar load, question the manufacturer as to the suitability of their product for the situation; consider changing the product to a material that will clearly withstand the loading; consider changes in design to forestall the loading.

If you have existing TPO roofing subjected to these situations you may well want to inspect the applications for incipient, developing or obvious local problems. The manufacturer can then be approached for direction in addressing or rectifying any deficiency.

Please inform the committee of any problem found as well as any reaction from the manufacturer involved.

T&R Committee


Ansel is offline  

Tags
roofing, roofing repairs


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Join Now... It's Fast and FREE!

Privacy Badge
I am a professional contractor
I am a DIY Homeowner
ContractorTalk.com is for
PROFESSIONAL CONTRACTORS ONLY!

At ContractorTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?


Content Relevant URLs by vBSEO 3.6.0